MUF 1200 Clamp On Ultrasonic Flow Meter (0.5)
MUF 1200 Clamp On Ultrasonic Flow Meter (0.5)

MUF 1200 Clamp On Ultrasonic Flow Meter (0.5)

MOQ : 1 Number

MUF 1200 Clamp On Ultrasonic Flow Meter (0.5) Specification

  • Sensor Type
  • Clamp On Ultrasonic
  • Housing Material
  • ABS/Aluminum
  • Response Time
  • <5 sec
  • Connectivity Type
  • RS-485, 4-20mA, OCT pulse
  • Length
  • Transducer cable standard 10m
  • Pressure Range
  • 1.6MPa (max)
  • Measurement Range
  • 0-99999999 m3 or gallon
  • Connector
  • Cable, Terminal Block
  • Storage Temperature
  • -40C to +120C
  • Temperature Range
  • Transducer: -40C to +160C
  • Measuring Units
  • m3/h, L/min, gallons, ft3, etc.
  • Resolution
  • 0.25mm/s
  • Connecting Type
  • Clamp-on transducer
  • Flow Rate
  • 0-32 m/s
  • Language
  • English, Chinese
  • Application Media
  • Water, Sewage, Oil, Chemicals, etc.
  • Equipment Type
  • Clamp On Ultrasonic Flow Meter
  • Frequency
  • Transducer: 1MHz (standard)
  • Color
  • Grey
  • Mounting
  • Clamp-on (non-invasive)
  • Dimension (L*W*H)
  • 210 x 90 x 50 mm (main unit)
  • Signal Type
  • Ultrasonic
  • Process Connection
  • Clamp-on
  • Output
  • 4-20mA, OCT Pulse, RS-485, Relay
  • Humidity %
  • 85% RH
  • Stability
  • 0.2% of measured value per year
  • Model
  • MUF 1200
  • Operating Temperature
  • -30C to +80C (main unit)
  • Protection
  • IP65
  • Diameter
  • DN15~DN6000 (0.5-240)
  • Velocity Range
  • 0~32 m/s
  • Material
  • ABS/Aluminum Alloy
  • Power Supply
  • AC 85-264V, DC 24V/500mA (optional)
  • Power Consumption
  • <2 Watts
  • Accuracy
  • 1% of reading
  • Display Type
  • LCD Display
  • Range
  • 0-32 m/s
  • Transducer Cable Extension
  • Up to 500m maximum (optional)
  • Pipe Material Supported
  • Steel, Stainless steel, PVC, Copper, Aluminum, Cast iron, Ductile, etc.
  • Data Logger
  • Internal memory, support data storage
  • Relay Output
  • 2 relays (AC 250V/5A, DC 30V/5A)
  • Pipe Condition
  • Full pipe, clean or dirty liquid
  • Transducer Type
  • Standard, high-temperature optional
  • Transducer Protection
  • IP68
  • Self-diagnosis
  • Built-in program
  • Output Frequency
  • 1~9999Hz pulse output
  • Display Resolution
  • 160 x 128 pixels
  • Power Frequency
  • 50/60Hz
  • Mounting Type
  • Wall-mount, panel, or portable (optional)
 

MUF 1200 Clamp On Ultrasonic Flow Meter (0.5) Trade Information

  • Minimum Order Quantity
  • 1 Number
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About MUF 1200 Clamp On Ultrasonic Flow Meter (0.5)

About

Explore the capabilities of the MUF 1200/MUF (B) 1200,designed for accurate, non-invasive monitoring of fluid flow and thermal energy. This advanced meter utilizes transit-time technology for precision measurements, offering a solution that enhances facility management without the need for complex installations. Ideal for HVAC systems, replacing defective units, aiding installation processes, and evaluating system performance, its ease of use and reliable data make it a top choice for optimizing operations and maintenance decisions.


Features

Wide Liquid Temperature
Data Logger Function
Thermal Energy Measurement Capability

Versatility Across Pipe Most Materials and Diameters

Specifications

Fluid types

Water

Pipe sizes

25 MM - 2000 MM

Flow Range

0.09ft/s 40ft/s

Flow accuracy

0.5% of

Repeatability

0.15%

Measurement parameters

Flow Meter- Instantaneous flow, totalized flow

Btu meter - Instantaneous energy, totalized energy, Instantaneous flow, totalized flow, supply temperature and return temperature.

Enclosures

Aluminium

Enclosure IP rating

IP65

Memory

EEPROM

Power supply

24 VDC/2A

Ambient temperature

32F to 140F ( 0C to 60C)

Standard outputs

4-20mA, Pulse

Network Connection

RS 485 Modbus RTU

Data logging

16 GB removable memory card

Operating Temperature range (Fluid)

Standard: 5F to 176F (-15C to 80C) Optional: 5F to 266F (-15C to 130C)

Process connections

Clamp on/Strap on

Materials

Aluminium alloy

Flow Transducer IP rating

IP68

Temperature Sensors

PT 1000

Certification

Calibration certification, CE, ISO



Advanced Ultrasonic Technology

The MUF 1200 employs state-of-the-art clamp-on ultrasonic technology to deliver reliable, accurate, and maintenance-free flow measurements. Its non-invasive design ensures zero risk of leaks and no process interruption during installation or maintenance. The built-in self-diagnosis program enhances operational reliability, providing consistent performance even in challenging conditions.


Flexible Installation and Connectivity

This flow meter offers wall-mount, panel, or portable configurations to suit site-specific requirements. The transducer cable supports up to 500 meters extension, enabling remote sensor placement. It features various connectivity options, including RS-485, 4-20mA, and relay outputs, ensuring seamless integration into existing control and monitoring systems.


Comprehensive Data Management

Equipped with an internal data logger and a clear display (160 x 128 pixels), the MUF 1200 records flow data for detailed analysis. Users can store and retrieve readings, thanks to the robust data storage capability. The device's multi-language support and intuitive interface make parameter setup and monitoring straightforward.

FAQ's of MUF 1200 Clamp On Ultrasonic Flow Meter (0.5):


Q: How does the MUF 1200 Clamp On Ultrasonic Flow Meter measure flow without pipe intrusion?

A: The MUF 1200 uses clamp-on ultrasonic sensors that are externally attached to the pipe. These sensors transmit and receive ultrasonic signals through the pipe wall, measuring the flow rate by detecting differences in transit time, without making contact with the liquid or interrupting the process.

Q: What types of pipes and fluids can the MUF 1200 be used with?

A: This flow meter works with various pipe materials, including steel, stainless steel, PVC, copper, aluminum, cast iron, and ductile iron. It accurately measures flow in liquids such as water, sewage, oil, chemicals, and other clean or dirty fluids as long as the pipe remains full.

Q: When is it beneficial to use a clamp-on ultrasonic flow meter instead of an inline model?

A: Clamp-on ultrasonic flow meters like the MUF 1200 are ideal when the process cannot be interrupted, or when installation inside the pipe is not possible. They minimize installation time and cost, avoid contamination, and are perfect for temporary measurements or challenging environments.

Q: Where can the MUF 1200 be installed and what mounting options are available?

A: The flow meter is suitable for wall-mount, panel-mount, or portable deployment. Its robust protection (IP65 for the main unit, IP68 for sensors) allows installation in humid, dusty, or industrial environments-indoors or outdoors-provided the ambient temperature and humidity ranges are observed.

Q: What is the process for setting up the MUF 1200, and is calibration required?

A: Setup involves mounting the sensors on the pipe's exterior, connecting the transducer cable, and inputting pipe and fluid parameters via the LCD interface. Factory calibration ensures accuracy, but regular maintenance and self-diagnosis features further support reliable measurements.

Q: How can stored data be accessed and integrated into control systems?

A: Flow data is logged in the device's internal memory and can be retrieved via the LCD display or exported using RS-485, 4-20mA, OCT pulse, or relay outputs. This allows seamless integration into SCADA or PLC systems for real-time monitoring and historical analysis.

Q: What are the main benefits of using the MUF 1200 flow meter for industrial and utility applications?

A: The MUF 1200 delivers high-accuracy (within 1% of reading), wide-ranging compatibility, non-invasive installation, and extensive data connectivity. It reduces downtime, is easy to operate, supports varied pipe sizes and materials, and remains reliable in tough operating conditions.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Ultrasonic Flow Meters Category

MUF (B) 1200 (1%)-Clamp on Ultrasonic BTU Meter

MUF (B) 1200 (1%)-Clamp on Ultrasonic BTU Meter

Minimum Order Quantity : 1 Unit

Range : Velocity: 32 m/s

Power Supply : AC 85264V, DC 24V, or builtin battery (optional)

Display Type : Other, 4line LCD with backlight

Accuracy : 1% of reading

MUF (B) 1200 (0.5%)-Clamp on Ultrasonic BTU Meter

MUF (B) 1200 (0.5%)-Clamp on Ultrasonic BTU Meter

Minimum Order Quantity : 1 Unit

Range : 032 m/s

Power Supply : AC 85~264V or DC 24V

Display Type : Other, LCD Digital Display

Accuracy : 0.5%

MUF 1200 (1%)-Clamp on Ultrasonic Flow Meter

MUF 1200 (1%)-Clamp on Ultrasonic Flow Meter

Minimum Order Quantity : 1 Unit

Range : 0.09 ft/s to 40 ft/s

Power Supply : 24 VDC / 2A (use 2A SMPS for AC power)

Display Type : Other, LCD digital display

Accuracy : 1% of measured value (with process calibration)

MUF 1200 Inline Ultrasonic Meter

MUF 1200 Inline Ultrasonic Meter

Price 106000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Range : 0.1 10 m/s

Power Supply : 220V AC/24V DC

Display Type : Other, LCD Digital Display

Accuracy : 1% of reading



Back to top