| Measurement Principle | FMCW (Frequency Modulated Continuous Wave) Radar |
| Accuracy | 3mm |
| Resolution | 1mm |
| Range | 0-30m |
| Process Connection | Standard : Threaded (BSP 1 1/2") Optional: Flanged (under DN 65) |
| Beam Angle | 3 or 8 |
| Power supply range | 24V DC Use 2-amp SMPS when employing AC power |
| Electrical Interface | M20l.5 |
| Communication mode | MODBUS HART |
| Outputs | 2-wire 4~20mA +RS485 |
| Cable inlet/plug | 1 blind plugged M20l.5 1 M20 XL.5 cable inlet |
| Frequency range | W-band [80 GHz] |
| Terminal | The cross section of the wire is 2.5mm |
| Fault signal | The current output is unchanged 21mA3.6mA |
| Integration time | (0 to 20)s, adjustable |
| Antenna form | Horn or lens antenna |
| Process pressure | -1 to 20 bar |
| Ambient storage temperature | -40~+80 |
| Process temperature | Threaded or Flanged Under DN65 Ideally Do Not Reach Over 80 Data Will Drifting (Either Higher Or Lower). Flanged Over DN65 Can Reach Under 200. |
| Process Connection | Standard :BSP 1 1/2", BSP 3 1/2", Optional : Flange DN40-DN200 (Universal Flange Could Do DN250) |
| Materials | Enclosure : Cast Aluminum Alloy Threaded : (Standard -PTFE) / (Optional -SS304) Flange : (Standard -PTFE) /(Optional - SS304) |
| Shell | Standard: Cast aluminum Optional: Stainless steel, POB |
| Seal between housing and housing | Silicone rubber |
| Shell window | Polycarbonate |
| Ground terminal | Stainless Steel |
| Blind Zone | Dependi ng On Low Level Blind zone is 0.15 meter for the sensors having capacity of 30 m measuring range. |
| Adjustment time | About 1 second (depends on parameter Settings) |
| Relative humidity | 95% |
| Shock-proof | Mechanical vibration l0m/s, (10 ~ 150)Hz |
| Class of protection | Display Head IP65, Probe IP68. |
ABOUT
Meet our MRL radar level technology - designed to deliver fast, accurate, and reliable level measurement. It offers stable performance across a wide range of applications, ensuring consistent results even in challenging conditions
Features
FAQ
Q: What is the MIAL Radar Level Meter used for?
A: It is used for accurate non-contact level measurement in tanks and process vessels
Q: Is the MIAL Radar Level Meter suitable for harsh environments?
A: Yes, it performs reliably in challenging industrial conditions.
Q: Can the radar level meter measure liquids with vapour or dust?
A: Yes, radar technology works effectively even in vapour and dusty conditions.
Q: Does the MIAL Radar Level Meter require direct contact with the liquid?
A: No, it provides non-contact level measurement.
Q: Is the MIAL Radar Level Meter suitable for industrial applications?
A: Yes, it is widely used in water, chemical, and process industries.



Price: