MUF 1200 (1%)-Clamp on Ultrasonic Flow Meter
MUF 1200 (1%)-Clamp on Ultrasonic Flow Meter

MUF 1200 (1%)-Clamp on Ultrasonic Flow Meter

MOQ : 1 Unit

MUF 1200 (1%)-Clamp on Ultrasonic Flow Meter Specification

  • Signal Type
  • Analog (4-20 mA), Pulse (0-9999 Hz)
  • Measuring Units
  • Instantaneous & totalized flow; Energy, flow, supply & return temperature
  • Connectivity Type
  • Modbus RTU RS485
  • Output
  • 4-20 mA, OCT pulse, alarm relay
  • Load Capacity
  • 750 max load
  • Protection
  • IP65 (enclosure), IP68 (transducer)
  • Flow Rate
  • 0.09 ft/s to 40 ft/s
  • Operating Temperature
  • 0C to 60C ambient; -15C to 60C standard fluid, up to 130C optional
  • Resolution
  • 0.2% of measured value (repeatability)
  • Sensor Type
  • PT1000 temperature sensor
  • Humidity %
  • Up to 99% RH, non-condensing
  • Measurement Range
  • 25 mm - 1200 mm pipe size
  • Application Media
  • Water
  • Stability
  • EEPROM data memory
  • Diameter
  • 25 mm - 1200 mm
  • Color
  • Grey/Black
  • Mounting
  • Clamp-on / Strap-on
  • Language
  • English
  • Material
  • ABS
  • Power Supply
  • 24 VDC / 2A (use 2A SMPS for AC power)
  • Accuracy
  • 1% of measured value (with process calibration)
  • Display Type
  • LCD digital display
  • Range
  • 0.09 ft/s to 40 ft/s
  • Transducer Type
  • Clamp-on
  • Memory Type
  • EEPROM
  • Operation
  • Non-intrusive
  • Pulse Output
  • Flow/energy/totalized
  • Equipment Type
  • Clamp-on Ultrasonic Flow Meter
  • Repeatability
  • 0.2% reading
  • Mounting Type
  • Wall-mount clamp
  • BTU Output
  • Available
  • Transducer Material
  • ABS plastic
  • Installation Orientation
  • Horizontal/vertical
  • Cable Length
  • 9 meters standard
  • User Interface
  • Button controlled
  • Fluid Property
  • Clean full pipes
  • Enclosure
  • Wall-mounted
  • Alarm Output
  • Relay output
  • Network
  • RS485 bus
  • Pipe Material
  • All metals, plastics
  • Linearity
  • 1%
 

MUF 1200 (1%)-Clamp on Ultrasonic Flow Meter Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 10 Units Per Month
  • Delivery Time
  • 30 Days
  • Main Domestic Market
  • All India
 

About MUF 1200 (1%)-Clamp on Ultrasonic Flow Meter

Feature

  • Wide Liquid Temperature
  • Thermal Energy Measurement Capability
  • Versatility Across Pipe Most Materials and Diameters

Operation and performance
Flow measurementUltrasonic diffrential transit-time Technology
Fluid typesWater
Fluid propertiesClean liquids in full (pressurized) pipes
Pipe sizes25 MM - 1200 MM
Pipe materialsmetallic and non-metallic materials.
Flow Range0.09 ft/s ~ 40ft/s
Flow accuracy (velocity)1% of the measured Value
Achievable with process calibration
Repeatability0.2% of the measured value
Linearity1%
Measurement parametersFlow Meter- Instantaneous flow, totalized flow
Btu meter - Instantaneous energy, totalized energy, Instantaneous flow, totalized flow, supply temperature and return temperature.
CertificationCalibration certification, CE, ISO
Electronics
EnclosuresABS Wall mounted enclosure
Enclosure IP ratingIP65
MemoryEEPROM
Power supply24 VDC/2A
Use 2-amp SMPS when employing AC power
Ambient temperature32F to 140F ( 0C to 60C)
HumidityUp to 99% RH,non-condensing
Standard outputAnalog output : 4 to 20 mA ,750 maximum load
Pulse output- 0~9999Hz, OCT, (min. and max. frequency is adjustable)
Standard Analog outputsFlow meter- 4 - 20 mA ,
Output programmed for instantaneous flow rate, 750 maximum load
BTU meter- 4 - 20 mA ,
Output programmed for instantaneous flow rate / instantaneous energy rate, 750 maximum load
Pulse outputsFlow meter- Pulse
Programmed for Flow rate / Positive totalized flow / Net-totalized flow (Forward
+ Reverse Flow Total), 0~9999Hz, OCT, (min. and max. frequency is adjustable).
BTU meter- Pulse
Programmed for Flow rate / Positive totalized flow / Net-totalized flow (Forward
+ Reverse Flow Total) / Energy rate / Energy totalized (Heat total/Cool total),0~9999Hz, OCT, (min. and max. frequency is adjustable)
Alarm Relay output
Network ConnectionModbus RTU RS 485
Cable9 m
Flow Transducer
Operating Temperature range (Fluid)Standard: 5F to 140F (-15C to 60C) Optional: 5F to 266F (-15C to 130C)
Process connectionsClamp on/Strap on
Materials TransducerABS
IP ratingIP68
Meter installation orientationHorizontal or Vertical
Energy measurement
Temperature sensorPT1000
Mountings
MountingsClamp on/Strap on
 

Technical Details 



Versatile, Non-Intrusive Measurement Solution

The MUF 1200 clamp-on ultrasonic flow meter offers a flexible installation method that requires no pipe cutting or process interruption. Its clamp-on ABS transducers support both horizontal and vertical positioning, making it suitable for diverse industries and pipe materials, including metals and plastics. The wall-mounted enclosure provides robust protection, and with standard 9-meter cable length, transducers can be conveniently placed for optimal signal strength and stability.


Advanced Features for Accurate Monitoring

Equipped with a PT1000 temperature sensor and multiple output formats (analog, pulse, relay, and Modbus RTU), the MUF 1200 captures real-time flow, energy, and temperature data. Its EEPROM memory ensures stable, reliable data storage, while the LCD display provides clear readouts in English. With high accuracy, repeatability, and broad measurement capability, it is ideal for water applications requiring precise flow and energy monitoring.

FAQ's of MUF 1200 (1%)-Clamp on Ultrasonic Flow Meter:


Q: How is the MUF 1200 Clamp-on Ultrasonic Flow Meter installed?

A: The MUF 1200 uses clamp-on transducers that attach externally to the pipe surface without the need to cut or interrupt the pipe. It supports both horizontal and vertical pipe mounting. The device's wall-mounted enclosure and a 9-meter standard cable enable flexible positioning for ease of installation.

Q: What types of pipes and fluids are compatible with this flow meter?

A: This flow meter is compatible with all metal and plastic pipes ranging from 25 mm to 1200 mm in diameter. It is designed for clean, full pipe applications and is especially suited for water flow measurement within the specified range.

Q: When should I choose a clamp-on ultrasonic flow meter like the MUF 1200?

A: You should choose the MUF 1200 when non-intrusive installation is required, such as in existing piping systems where process shutdown is costly or impractical. Its clamp-on design makes it ideal for applications needing minimal maintenance and fast deployment.

Q: Where can the MUF 1200 be used effectively?

A: The MUF 1200 is suitable for a variety of industrial environments, provided the ambient temperature is between 0C and 60C and humidity is up to 99% RH non-condensing. Its IP65-rated enclosure and IP68 transducers allow for use in moist or challenging locations.

Q: What outputs and connectivity options does the MUF 1200 provide?

A: The MUF 1200 supports analog (4-20 mA), pulse (0-9999 Hz), alarm relay outputs, and digital connectivity via Modbus RTU RS485. These allow integration with a wide range of monitoring, control, and automation systems.

Q: How does the MUF 1200 ensure measurement accuracy and stability?

A: The device offers 1% accuracy of measured value with process calibration, and 0.2% repeatability. Built-in EEPROM memory protects data integrity, and robust sensor design ensures stability even in high humidity or fluctuating temperatures.

Q: What are the main benefits of using the MUF 1200 flow meter?

A: Key benefits include non-intrusive installation, wide compatibility with pipe materials and sizes, real-time monitoring of flow and energy parameters, multiple output options, and simple operation via a button-controlled user interface. It enables significant time and maintenance savings over traditional in-line meters.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Ultrasonic Flow Meters Category

MUF 1200 Clamp On Ultrasonic Flow Meter (0.5)

MUF 1200 Clamp On Ultrasonic Flow Meter (0.5)

Minimum Order Quantity : 1 Number

Power Supply : AC 85264V, DC 24V/500mA (optional)

Sensor Type : Clamp On Ultrasonic

Display Type : Other, LCD Display

Range : 032 m/s

MUF (B) 1200 (1%)-Clamp on Ultrasonic BTU Meter

MUF (B) 1200 (1%)-Clamp on Ultrasonic BTU Meter

Minimum Order Quantity : 1 Unit

Power Supply : AC 85264V, DC 24V, or builtin battery (optional)

Sensor Type : Clampon ultrasonic, PT1000 temperature sensor

Display Type : Other, 4line LCD with backlight

Range : Velocity: 32 m/s

MUF (B) 1200 (0.5%)-Clamp on Ultrasonic BTU Meter

MUF (B) 1200 (0.5%)-Clamp on Ultrasonic BTU Meter

Minimum Order Quantity : 1 Unit

Power Supply : AC 85~264V or DC 24V

Sensor Type : Clampon Ultrasonic

Display Type : Other, LCD Digital Display

Range : 032 m/s

MUF 1200 Inline Ultrasonic Meter

MUF 1200 Inline Ultrasonic Meter

Price 106000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Power Supply : 220V AC/24V DC

Sensor Type : Clampon/Inline Ultrasonic

Display Type : Other, LCD Digital Display

Range : 0.1 10 m/s



Back to top