MUF(B) 1200-Inline Ultrasonic BTU Meter Specification

  • Diameter
  • 15-1200 mm
  • Color
  • Silver / Blue
  • Connecting Type
  • Flanged / Threaded
  • Sensor Type
  • Ultrasonic Clamp-on / Insertion / Inline
  • Flow Rate
  • 0.03-12 m/s
  • Length
  • Standard as per diameter
  • Language
  • English
  • Stability
  • Long-term stability
  • Pressure Range
  • 1.6 MPa
  • Wind Speed
  • -
  • Process Connection
  • Flanged / Threaded
  • Humidity %
  • < 85% RH
  • Measurement Range
  • 0.03-12 m/s (flow), 0-95C (temperature)
  • Mounting
  • Inline
  • Connectivity Type
  • Wired / MODBUS
  • Application Media
  • Water, Hot Water, Chilled Water, HVAC Media
  • Load Capacity
  • -
  • Dimension (L*W*H)
  • Varies by diameter
  • Signal Type
  • Ultrasonic
  • Response Time
  • < 3s
  • Equipment Type
  • Ultrasonic BTU Meter
  • Current Range
  • -
  • Output
  • 4-20mA, Pulse, RS485 MODBUS
  • Storage Temperature
  • -25C to +70C
  • Frequency
  • -
  • Operating Temperature
  • -10C to +55C (transmitter)
  • Resolution
  • 0.001 m3/h
  • Capacity
  • 100-10,000 m3/h
  • Temperature Range
  • 0-95C
  • Measuring Units
  • BTU, MWh, KWh, GJ, m3/h, L/h
  • Cut Size
  • -
  • Protection
  • IP68
  • Material
  • Stainless Steel / Carbon Steel / PVC
  • Power Supply
  • 24V DC / Battery / 220VAC
  • Power Consumption
  • < 1.5 W
  • Accuracy
  • 1.0%
  • Display Type
  • LCD Display
  • Range
  • 0.03-12 m/s (flow)
  • Power Backup
  • Up to 6 years (battery option)
  • Error Indication
  • Self-diagnostics, display codes
  • Approval/Certification
  • CE, ISO9001
  • Installation Orientation
  • Horizontal / Vertical
  • Data Logger
  • Integrated / Optional
  • Transducer Cable Length
  • 10m (standard), extendable
 

MUF(B) 1200-Inline Ultrasonic BTU Meter Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 10 Units Per Month
  • Delivery Time
  • 30 Days
  • Main Domestic Market
  • All India
 

About MUF(B) 1200-Inline Ultrasonic BTU Meter

Feature

  • Consistent without any-Moving-Parts Design
  • Wide flow range
  • Precision Maintained Across a Broad Flow Spectrum
  • Dual-Intuitive Backlit Screen and UserFriendly Interface
  • Integrated Interval Data Logging Capability
  • Versatile Communication Options and Multiple Outputs
  • Low Maintenance 
Operation and performance
Flow measurementUltrasonic diffrential transit-time Technology
Fluid typesSingle medium, including a non-conductive medium and most clean liquids.
Fluid propertiesClean liquids in full (pressurized) pipes
Pipe sizes50 MM - 300 MM
Pipe materialsmetallic and non-metallic materials.
Flow Range0.09 ft/s ~ 40ft/s
Flow accuracy1% of the measured Value
Achievable with process calibration
Repeatability0.2% of the measured value
Linearity1%
Measurement parametersFlow Meter- Instantaneous flow, totalized flow
Btu meter - Instantaneous energy, totalized energy, Instantaneous flow, totalized flow, supply temperature and return temperature.
CertificationCalibration certification, CE, ISO
Electronics
EnclosuresABS (Wall mounted enclosure )
Enclosure IP ratingIP65
MemoryEEPROM
Power supply24 VDC/2A
Use 2-amp SMPS when employing AC power
HumidityUp to 99% RH,non-condensing
Standard Analog outputsFlow meter- 4 - 20 mA ,(Output programmed for instantaneous flow rate, 750 maximum load)
BTU meter- 4 - 20 mA , (Output programmed for instantaneous flow rate / instantaneous energy rate, 750 maximum load)
Pulse outputsFlow meter- Pulse
Programmed for Flow rate / Positive totalized flow / Net-totalized flow (Forward + Reverse Flow Total), 0~9999Hz, OCT, (min. and max. frequency is adjustable).
BTU meter- Pulse
Programmed for Flow rate / Positive totalized flow / Net-totalized flow (Forward + Reverse Flow Total) / Energy rate / Energy totalized (Heat total/Cool total),0~9999Hz, OCT, (min. and max. frequency is adjustable)
Network ConnectionModbus RTU RS 485
Data logging8 GB removable memory card
Cable10 m
Flow Tube
Operating Temperature range (Fluid)5F to 176F (-15C to 80C)
Nominal Pressure1.6 Mpa
Process connectionsANSI 150 Flanges
MaterialsFlow Tube : Stainless steel Flange : Carbon Steel Optional: Stainless steel
IP ratingIP68
Meter installation orientationHorizontal or Vertical
In a vertical installation, it is essential that the pipe be fully filled, with the flow direction oriented from bottom to top.
Energy measurement
Temperature sensorPT1000
Mountings
InsertionWetted Immersion Temperature sensor with Thermowell
 

 




High-Precision Energy Measurement

Delivering 1.0% accuracy and advanced self-diagnostics, the MUF(B) 1200 ensures reliable BTU measurement for water, hot water, chilled water, and diverse HVAC media. Integrated and optional data logging enhance performance monitoring and energy management in commercial and industrial facilities.


Flexible Installation and Robust Design

Engineered for both horizontal and vertical pipelines, this inline ultrasonic BTU meter accommodates pipe diameters from 15 to 1200 mm. Its IP68 protection, stainless steel or PVC construction, and multiple mounting options (flanged/threaded) ensure longevity in demanding environments.


Versatile Power and Communication Options

Enjoy seamless operation with selectable power supplies (24V DC, 220VAC, or battery) and efficient power consumption (<1.5 W). Multiple connectivity types, including MODBUS and 4-20mA, enable easy integration into building management and automation systems.

FAQ's of MUF(B) 1200-Inline Ultrasonic BTU Meter:


Q: How does the MUF(B) 1200-Inline Ultrasonic BTU Meter measure energy usage in water systems?

A: The MUF(B) 1200 uses ultrasonic technology to accurately measure the flow of water and its temperature differentials, allowing the calculation of BTU, MWh, KWh, or GJ used in a system. It is suitable for various water-based applications, including hot water, chilled water, and HVAC systems.

Q: What installation orientations are possible for this BTU meter?

A: This ultrasonic BTU meter can be installed in both horizontal and vertical pipeline orientations, accommodating a wide range of system designs and site conditions.

Q: When should the transducer cable length be extended, and what is the standard length provided?

A: The meter comes with a standard 10-meter transducer cable. It should be extended when the installation site requires the transmitter to be located farther from the transducer, ensuring optimal signal quality and convenience during setup.

Q: Where can this meter be used with respect to industry and environment?

A: The MUF(B) 1200 is ideal for commercial, industrial, and HVAC environments where precise energy or flow measurement is required. The IP68 protection and robust materials make it suitable for demanding installations, including pump rooms and outdoors.

Q: What is the process for reading and logging data from the meter?

A: Data can be displayed in real time on the LCD screen or transmitted via 4-20mA, pulse, or RS485 MODBUS outputs for integration with other monitoring systems. The integrated or optional data logger can store measurement records for tracking and analysis.

Q: How does the self-diagnostic feature enhance meter reliability and usage?

A: The self-diagnostic system continuously monitors the meter's status, displaying error codes on the LCD if an issue arises. This helps users quickly identify and address problems, ensuring long-term measurement accuracy and minimal downtime.

Q: What are the main benefits of choosing this ultrasonic BTU meter?

A: Users benefit from high accuracy, flexible installation, multiple power and communication options, robust durability, and long-term stability. The meter's certifications, self-monitoring capabilities, and low power consumption make it a reliable choice for energy management.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Ultrasonic Flow Meters Category

MUF (B) 1200 (1%)-Clamp on Ultrasonic BTU Meter

MUF (B) 1200 (1%)-Clamp on Ultrasonic BTU Meter

Minimum Order Quantity : 1 Unit

Accuracy : 1% of reading

Diameter : DN15DN6000mm

Range : Velocity: 32 m/s

Sensor Type : Clampon ultrasonic, PT1000 temperature sensor

MUF (B) 1200 (0.5%)-Clamp on Ultrasonic BTU Meter

MUF (B) 1200 (0.5%)-Clamp on Ultrasonic BTU Meter

Minimum Order Quantity : 1 Unit

Accuracy : 0.5%

Diameter : DN15~DN6000 mm

Range : 032 m/s

Sensor Type : Clampon Ultrasonic

MUF 1200 (1%)-Clamp on Ultrasonic Flow Meter

MUF 1200 (1%)-Clamp on Ultrasonic Flow Meter

Minimum Order Quantity : 1 Unit

Accuracy : 1% of measured value (with process calibration)

Diameter : 25 mm 1200 mm

Range : 0.09 ft/s to 40 ft/s

Sensor Type : PT1000 temperature sensor

MUF 1200 Inline Ultrasonic Meter

MUF 1200 Inline Ultrasonic Meter

Price 131915 INR / Unit

Minimum Order Quantity : 1 Unit

Accuracy : 1% of reading

Diameter : DN15 DN600

Range : 0.1 10 m/s

Sensor Type : Clampon/Inline Ultrasonic